Eaton 5S1500LCD battery teardown

Bare cells needed
2 x 12 V 9 Ah
Max DC draw
45.7 A
OEM cartridge
No SKU in our sources
Cell size
151 x 65 x 94 mm
In inches
5.94 x 2.56 x 3.70 in
Terminal
F2
Rating
1500 VA / 900 W
Topology
Line Interactive
Waveform
Not verified
Transfer time
Under 5 ms
OEM list price
not published
DC bus
24 V
Last verified
2026-11-01
LiFePO4 at full load
RED

What battery does the 5S1500LCD actually use?

The 5S1500LCD uses Eaton 5S cell pair, which holds two 12 V blocks in series rated 9 Ah on a 24 V DC bus. Each block fits a 151 x 65 mm bay with F2 terminals. This model has no serial-number split that we could find.

Specs and where each one comes from. T1 is the manufacturer, T2 is a teardown or industrial cross-reference.
SpecValueSource
VA and watts1500 VA / 900 WT1 cdn.blueally.com
TopologyLine InteractiveT1 eaton.com
Waveform, in the OEM's wordsNot verifiedT1 cdn.blueally.com
Transfer timeUnder 5 msT1 eaton.com

OSI lists 5.94 x 2.55 x 3.87 in with .250 faston tabs, two per unit.

PLAN VIEW, TO SCALE: CASE FORMATS151 mm65Standard 7-9 Ah (this page)CSB HR1234WF2, 94 mm case height151 mm51Slim 6 AhCSB HR1224WF2F1, 94 mm case height90 mm705 Ah cubeCSB HR1221WF2, 102 mm case heightFASTON TAB WIDTH, ENLARGEDF1 4.75 mm / 0.187"F2 6.35 mm / 0.250"

How many DC amps does the 5S1500LCD pull?

At its full 900 W rating, the 5S1500LCD pulls about 45.7 A from its 24 V bus, and about 52.3 A as the battery sags to 21 V cutoff. Those figures assume 82% inverter efficiency, because Eaton doesn't publish one for battery mode.

DC current by AC load, on the 24 V bus and at 21 V cutoff
AC loadNominalAt cutoff
25 W1.3 A1.5 A
60 W3.0 A3.5 A
100 W5.1 A5.8 A
200 W10.2 A11.6 A
300 W15.2 A17.4 A
450 W22.9 A26.1 A
900 W45.7 A52.3 A

Is LiFePO4 safe in the 5S1500LCD?

A 12 A BMS limits the 5S1500LCD to about 236 W, well below its 900 W rating. At full load the verdict is RED. Packs in series can drift apart on the charger, so balance them first. Drag the slider below to test your own load.

25 WBMS ceiling 236 W900 W

RED: BMS trip hazard

DC draw now
12.7 A
At 21 V cutoff
14.5 A
Safe AC load
236 W
Stock 9 Ah AGM24 min
12V 9 Ah high-rate AGM29 min
LiFePO4 10 Ah0 min (BMS OVERCURRENT TRIP)

5S1500LCD: lead-acid anchored to OEM half and full-load runtimes, LiFePO4 on a flat energy curve with inverter tare, at 82% inverter efficiency. A real inrush can trip a BMS below this ceiling.

Maximum safe AC load by BMS continuous rating, on the 24 V bus
BMS continuousSafe AC loadShare of 900 W
10 A197 W22%
12 A236 W26%
15 A295 W33%
20 A394 W44%

Balance every pack first. Two independent BMS boards on one series charger can drift apart, and one can cut off early. Series drift and 0 V lockout explained.

How long will the 5S1500LCD run on each battery?

Eaton publishes about 13 min at 420 W and 2 min at 900 W on the stock cells, and our curve passes through both points. The 12V 9 Ah high-rate AGM option adds runtime in the same case. Drag the slider for your own load.

Estimated runtime in the three options, with a 12 A BMS for LiFePO4
AC loadStock 9 Ah12V 9 Ah high-rate AGMLiFePO4 10 Ah
25 W6.0 hr6.4 hr4.3 hr
60 W2.2 hr2.4 hr2.4 hr
100 W71 min82 min1.6 hr
200 W31 min38 min53 min
300 W19 min24 min0 min, BMS trip
450 W11 min14 min0 min, BMS trip
900 W2.0 min2.6 min0 min, BMS trip
Eaton's published runtime against raw Peukert and this site's calibrated curve
LoadEaton publishedRaw PeukertThis siteSource
420 W13 min13 min13 minT1 cdn.blueally.com
900 W2 min5.1 min2 minT1 cdn.blueally.com

Upgraded AGM scales from the anchored curve, with k = 1.18 standard and 1.12 high-rate. LiFePO4 uses a flat energy curve with inverter tare. Method.

Which replacement should you buy for the 5S1500LCD?

There are three routes for the 5S1500LCD. Path A swaps in two bare cells and reuses your harness. Path B adds LiFePO4 for loads under 394 W, by the listing's 20 A claim. Path C replaces the whole UPS, which makes most sense for units over six years old.

The three routes compared
PathBest forLoad limitMain risk
A: bare SLA swapLowest cost, any load900 WTerminal or case mismatch
B: drop-in LiFePO4Light loads, long life394 W on the listed 20 ABMS trip, charger mismatch
C: native LiFePO4 UPSA unit over 6 years old, or high loads1000 WSlower transfer than this UPS

Path A: the bare-cell SLA swap

Surge-safe, because AGM has no BMS to trip.

2 x Mighty Max ML9-12 12V 9Ah F2
Standard AGM, F2. The like-for-like choice.
Check Prime Price & Stock on Amazon →
2 x CSB HR1234WF2 12V 9Ah High Rate (the high-rate option)
High-rate AGM, F2. Holds up best at UPS discharge rates.
Check Prime Price & Stock on Amazon →

Path B: drop-in LiFePO4

Safe to about 394 W if the listing's 20 A BMS is continuous, or 236 W at 12 A. Check your load before you click.

2 x 12.8V 10Ah LiFePO4, F1 terminal
Listing claims a 20 A BMS and doesn't say whether that is continuous.
Check Prime Price & Stock on Amazon →
2 x F1 to F2 terminal adapters, pair (4 adapters needed)
One pair covers one cell.
Check Prime Price & Stock on Amazon →

Path C: a native LiFePO4 UPS

Worth it if this UPS is 6 or more years old, if a fault above isn't a battery problem, or if you need more than the BMS limit. Listings and reviews put Goldenmate's transfer at 8 to 20 ms, against this unit's Under 5 ms, so check that your PC tolerates it.

Goldenmate 1500VA/1000W LiFePO4 UPS
Built-in LiFePO4, for loads above 800 W.
Check Prime Price & Stock on Amazon →
EcoFlow DELTA 3 Plus
Listing claims 10 ms switch-over. A power station, not a tower UPS.
Check Prime Price & Stock on Amazon →

How do you move the 5S1500LCD harness to bare cells?

You move the factory jumper and leads from the old blocks to the new ones, in the same polarity. Unplug the UPS first, and tape each lead as it comes off, because the battery stays live. Sealed sleds must be opened first. No soldering is needed.

FRONT ELEVATION: 2 x 12 V, 24 V DC BUSCELL 1tabs F2+−CELL 2tabs F2+−RED TO UPS (+)BLACK TO UPS (−)each cell 151 x 65 x 94 mm
  1. Shut down the load, turn the UPS off and unplug it from the wall.
  2. Take a photo of the wiring. Open the battery door or sled and slide the pack out.
  3. Pull the red clip off the positive tab, and tape it straight away.
  4. Remove the black lead and tape it. Then lift off the jumper between the cells, with its fuse if your harness has one.
  5. Check the new cells have the right size and tabs, then add any adapters from the parts list.
  6. Fit the jumper first, from the positive of one cell to the negative of the other. Fit the leads one at a time, matching your photo, and remove the tape only from the lead you are fitting.
  7. Measure about 25 to 27 V across the two outer leads before you close the pack. Slide it back, plug in and charge for the time the manual gives before relying on it.
  8. Recycle the old cells at a battery retailer. Never bin lead-acid.

Sixty seconds is the best case for a loose-cell unit. Sealed sleds need opening first, and opening them may affect your warranty and Eaton's equipment guarantee.

How much do you save over the Eaton 5S cell pair?

We can't state a saving for Eaton 5S cell pair, because we found no published list price for it. Any figure here would be a guess, so this page leaves it out rather than estimating one for you. Compare the list price with your own quote.

What we have
ItemStatus
Eaton 5S cell pair list pricenot published
Verified bare-cell referencenone

What do the 5S1500LCD alarms and fault codes mean?

We don't have an alarm table for the 5S1500LCD, because the sources we captured don't include one. Rather than guess at what a beep means, check the manual that came with your unit before you buy a replacement battery or contact support.

We could not get this model's alarm table, so we list nothing rather than guess. Check the manual that came with your unit.

Alarm table status
5S1500LCDNot captured

How do you reach the battery in the 5S1500LCD?

We have no verified door procedure for the 5S1500LCD. The manufacturer says this battery should be replaced by qualified personnel. Treat the unit as a service item, and don't open the case to find out how it comes apart. Contact the manufacturer if you are unsure.

Physical access for the 5S1500LCD, from the OEM manual where stated
FieldValueSource
Battery door accessNo procedure captured. Treat as a service itemnone
Cell orientationNot stated in the manual we capturednone
Harness connector typeNot stated in the manual we capturednone
Cell layout2 x 12 V, in seriesverified