CyberPower RB1270X4 teardown

Inside
4 x 12 V 7 Ah
Wiring
24 V, 2 pairs (assumed)
List price
$264
Cell size
151 x 65 x 94 mm
Terminal
F2
Evidence on cell count
verified

What is inside the RB1270X4?

RB1270X4 holds four 12 V blocks, assumed to be two parallel pairs, rated 7 Ah, giving a 24 V bus. CyberPower publishes the cell count. Both blocks carry the same current and should be replaced together. Check the label on your old blocks before ordering a replacement.

FRONT ELEVATION: 4 x 12 V, 24 V DC BUS, 2 PARALLEL PAIRS (ASSUMED)CELL 1tabs F2+−CELL 2tabs F2+−CELL 3tabs F2+−CELL 4tabs F2+−RED TO UPS (+)BLACK TO UPS (−)each cell 151 x 65 x 94 mmPLAN VIEW, TO SCALE: CASE FORMATS151 mm65Standard 7-9 Ah (this page)CSB HR1234WF2, 94 mm case height151 mm51Slim 6 AhCSB HR1224WF2F1, 94 mm case height90 mm705 Ah cubeCSB HR1221WF2, 102 mm case heightFASTON TAB WIDTH, ENLARGEDF1 4.75 mm / 0.187"F2 6.35 mm / 0.250"
Every ledger row for RB1270X4
FieldValueQuoteSource
cells4Battery Quantity | 4T1 cyberpowersystems.com
cell ah7contains four 12V/7AHT1 cyberpowersystems.com
envelope mmnullBattery SizeT1 cyberpowersystems.com
msrp usd264MSRP | $264T1 cyberpowersystems.com
envelope in8.27 x 2.72 x 12.92RB1270X4 Dimensions W×H×D (in.): 8.27 × 2.72 × 12.92T1 cyberpowersystems.com
not before 2009Not compatible before January 2009Not compatible with OR1500LCDRM2U UPS sold before January 2009T1 cyberpowersystems.com
terminalF2Cyber Power OR1500LCDRM2U Requires 4 batteries per unit | .250" faston | 5.94 x 2.56 x 3.70T2 osibatteries.com

Which UPS models use the RB1270X4?

Of the 35 models we track, RB1270X4 fits OR1500LCDRM2U. That list comes from the manufacturer's pages, and they sometimes disagree with reseller listings. Where a model splits by serial number, its UPS page shows which prefix takes this cartridge, so check your label before you order.

Models on this site that use RB1270X4
UPSRatingSerial condition
OR1500LCDRM2U1500 VA / 900 Wall serials

Which bare cells replace the RB1270X4?

Replace RB1270X4 with four 12V 9 Ah F2 (same case as 7 Ah) cells and reuse the factory harness. CyberPower lists 8.27 x 2.72 x 12.92 in for the pack. A reseller confirms the terminal type, so no guesswork is needed. Keep the old harness, because bare cells ship without leads.

4 x Mighty Max ML9-12 12V 9Ah F2
Standard AGM, F2. The like-for-like choice.
Check Prime Price & Stock on Amazon →
4 x CSB HR1234WF2 12V 9Ah High Rate (the high-rate option)
High-rate AGM, F2. Holds up best at UPS discharge rates.
Check Prime Price & Stock on Amazon →

Can LiFePO4 replace the RB1270X4?

We can't recommend LiFePO4 for RB1270X4. The bus wiring is unverified, and four independent BMS boards in one pack multiply the balance risk. Showing a link would mean guessing about fit. Buy the lead-acid cell or a factory LiFePO4 UPS instead, and see our method page for how we test fit.

How much does the RB1270X4 cost against bare cells?

RB1270X4 lists at $264. Four bare cells cost about $139.76 at a non-Amazon single-unit reference price, a saving of roughly 47%. The reference is a CSB block at one store, and it is not an Amazon price. Reusing the harness is what makes this work.

Official RB1270X4 MSRP: $264. Typical Commodity Bare-Cell Band (Non-Amazon Reference): about $139.76 for 4 x CSB HR1234WF2. Reuse your factory wire harness to save about 47% against the OEM cartridge MSRP.